high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation  State Grid-compliant  wire&cable
high quality XLPE insulation State Grid-compliant wire&cable
$10-200
FOB
MOQ:
200
Shipping:
Express Delivery, Ocean freight, Land freight
Sample:Free supportGet samples
Product details
FAQ
Essential details
MOQ:200
Lead time:7 days upon 30% deposit
Shipping:Express Delivery, Ocean freight, Land freight
Specification Number:YJV223C35KV025-500
Product Introduction

APPLICATION

Power cables for supplying medium-voltage (MV) equipment. Suitable for applications in tunnels, underground mines, indoor and outdoor power networks, and cable duct installations.      

CONSTRUCTION

Conductor

Copper/Aluminum conductor

 

Semiconducting Layer Over The Conductor

Semiconducting XLPE

Insulation

XLPE (cross-linked Polyethylene)

Semiconducting Layer Over The Insulation

Semiconducting XLPE

Screen

CU(copper) tape

Filler

Polypropylene rope

Wrap tape

Non-woven fabric

Bedding

Polyvinyl chloride (PVC)

Armour

Steel tape armoured

Outer Sheath

PVC(polyvinyl chloride)

Core Identification

Red ,Yellow & Green or as you specify

Available Nominal Cross-sectional Areas

25-500 sqmm

CHARACTERISTICS

Rated Voltage  (Uo/U):3.6/6 kV,6/6kV,6/10kV,8.7/10kV,8.7/15kV,12/20kV,18/20kV,18/30kV,21/35kV,26/35kV
Test Voltage: 

3.6/6 kV & 12.5 kV (5 min)                                              6/6 & 6/10 kV & 21 kV (5 min)

8.7/10 & 8.7/15 kV & 30.5 kV (5 min)                              12/20 kV & 42 kV (5 min)

18/20 & 18/30 kV & 63 kV (5 min)                                 

21/35kV & 53 kV (30 min)                                                 26/35 kV & 65 kV (30 min)

Max Short-Circuit Temperature : 250℃ (max duration 5s)
Max Operating Temperature: 90℃
Min Installation Ambient Temperature: 0℃ 
Temperature Rating (Fixed Installation): -20℃ to 90℃ 
Minimum Bending Radius
Single-core: 15×OD±5%
Multi-core: 12×OD±5%  (Note: OD refers to the outer diameter of the cable)


  